Cathode Ray Experiments KED4304

Cathode ray tube

Ask About This Product

Description

Experiments that can be carried out:

  • Vacuum experiments
  • Producing cathode rays,
  • Paschen curve (Ar, N, He, air)
  • Plasma current-voltage characteristics
  • Deflection and oscillations in a magnetic field

Standard Materials
Cathode ray tube, 1 mechanical vacuum pump, 1 vacuum gauge, DC or AC high-voltage power supply (made to the required values), ammeter, voltmeter, resistor set, Helmholtz coils for an external magnetic field, connecting cables

Notes
This experiment set teaches the working principle of the vacuum pump. The colour of the plasma formed by ionizing different gases admitted to the vacuum tube at low pressure, and the ion beam produced by the plasma ions, can be observed. Deflections of this ion beam by an externally applied magnetic field can be measured, and changes in its shape with pressure studied. Current-voltage characteristics can be measured with 2 electrodes inserted into the plasma. This type of cathode tube system can be designed to order, with high-voltage inputs and outputs, BNC connector inputs and outputs, and multiple RS232 or similar connector inputs and outputs.