Programmable Power Supply 0-32V 0-20A 640W - ALR3220

Ask About This Product

Description

0 - 32V / 0 - 20A
POWER: 640 watts

LARGE GRAPHIC DISPLAY
TOUCH : Touch-sensitive keypad
CONNECTED : USB, RS232, RS485 & 0-10 V, isolated

LABVIEW
ELEGANT : New, lightweight design
SPACE-SAVING : in a compact vertical case
PRACTICAL : Lightweight, with built-in handle and cord
storage area.
QUIET : Silent, temperature-controlled fan cooling.
LOCKING : Configuration & standby

Voltage
• Floating outputs: on 4 mm safety terminals on the front panel
and on a screw terminal block for 2.5 mm² on the rear panel.
• Automatic constant voltage operation.
• Adjustable from 0 to 32.00 volts (0 to ±10 mV); resolution: 10 mV.
• Setting accuracy: < 0,03% that to say ±10 mV.
• Regulation: < 50mV for a load change from 10 to 90%.
< 1mV for a ±10% line change.
•Ripple: < 1mV rms including :
< 3 mV peak to peak of noise (BP 20 MHz)
< 15mV peak to peak of switching spikes
• Internal resistance: < 4mΩ.
• Display: 4 digits on graphic LCD.
• Measurement accuracy: < 0,03% that to say ±10 mV.
Current
• Automatic constant current operation.
• Adjustable from 0 to 20.00 amps; resolution: 10 mA.
• Setting accuracy: < 0,05% that to say ±10 mA.
• Regulation: < 10mA for a load charge from 10 to 90%.
< 1mA for a ±10% line charge.
• Ripple: < 6mA peak to peak or 2mA rms.
• Display: 4 digits on graphic LCD.
• Measurement accuracy: < 0,05% that to say ±10 mA.
Protections
• Against short circuits, by current regulation.
• Against overtemperature, by fan and thermal circuit breaker.
• Against overcurrent on the mains input, by internal fuses.
Miscellaneous and functions
• Display: graphic LCD, 128 x 64 pixels with white backlight.
Display of all parameters
CV (constant voltage) or CC (constant current) mode
• Memories: 16, including 15 configurable.

• OVP/OCP: protection against overvoltage and overcurrent, adjustable from 0 to max.
• Functions: 5 functions available on U or I
(square, positive and negative ramp, rise or fall time),
time adjustable from 10 ms to 100 s.
• Remote sensing: automatic function on the front output.
4-wire mode on the rear terminal blocks.
Compensation of voltage drop in the leads: 2 V
• Standby: output enable/disable and power supply standby.
Interfaces
All interfaces are isolated from the output (150 V max).
• USB, RS232 and RS485 as standard.
• Standard LabVIEW drivers
• Analogue control 0 – 10 V: U and I via direct input 0 - 10 V
or a 10K potentiometer or 10K adjustable resistance.
On removable screw terminal blocks at the rear.
• Safety: Class I, enhanced safety between mains input and outputs.
Complies with EN 61010-1, CAT II.
• EMC: complies with EN 61326-1 and EN 55011.
• Input voltage: 220 - 240 volts ±10%, 50 / 60 Hz.
• Mains input: CE14 socket with C13 cable, 2 poles + earth
• Power consumption: 770 W max.
• Efficiency: > 84% at maximum power.
• Operating temperature: +5 to +40°C.
• Temperature coefficient /°C: 0.01% for voltage; 0.05% for current.
• Voltage to earth: 100 V max.
• Presentation: front panel with touch-sensitive keypad, rear panel with
handle and cord storage area, metal case with epoxy finish.